Product DetailsThe system has a PLC automatic control system, which can safely monitor storage and dosing, and can achieve comprehensive data remote transmission and monitoring with the upper machine.Product parameterEffective chlorine production: 50-15000g/HEffective chlorine concentration: 8-10g/LInstalled power: 0.3-90KWHost size: 700 * 450 * 900Delivery cycle: 25 daysWhatsApp:+86 19953182842Email: henry@hoclshine.comProduct advantage1、Adopting automatic dosing of residual chlorine+flow, closed-loop control dosing method, with independent software copyright registration rights.2、The dosing
Contact Now
Product DetailsThe pre-treatment water softener and salt dissolving system can be automatically adjusted according to different yields. Product parameterEffective chlorine production: 50-15000g/HEffective chlorine concentration: 8-10g/LInstalled power: 0.3-90KWHost size: 1600 * 1000 * 2000mmDelivery cycle: 25 daysWhatsApp:+86 19953182842Email: henry@hoclshine.comProduct advantage1、Tap water flows into the water softener, and calcium and magnesium plasma are removed through resin separation technology to generate soft water.A portion of the generated soft water enters the clean water tank
Contact Now
Hygiene status of trash roomsAfter 24 hours of piling up wet garbage, a large number of pathogens can be detected, such as cholera, hemolytic streptococcus, coliform bacteria, mycobacterium tuberculosis, hepatitis virus (A, E), HIV virus and other nearly 20 kinds of pathogens, and Garbage bins, drop-in points, transfer stations, and non-sealed packages of garbage in transfer vehicles have an unpleasant odor, and are particularly prone to breeding mosquitoes and flies.
Contact Now
Shenghui SHC-1000S Hypochlorous acid generator manufacturers electrolytic cell is equipped with diaphragm structure, the electrode is made of tubular titanium base coated with ruthenium and iridium, the intermediate diaphragm is made of titanium ion film, the service life is more than 10,000 hours, the control system is self-developed microcomputer system, automatic operation, continuous operation. It can monitor the electrolytic current in real time, and control the electrolytic current through the main control board.
Contact Now
Product OverviewOn-site hypochlorite generation system creates sodium hypochlorite (NaClO) straight at the area where it will certainly be used. This removes the need for moving and keeping pre-made solutions.
Contact Now
SHINE independently developed non-diaphragm electrolytic HCL to produce high-concentration hypochlorous acid disinfectant,without the need for a pre-purified water system,stable flow rate and adjustable concentration.The electrolytic cell can be used for 3 yearsProduct parameterConcentration: 50-500PPM (adjustable)Flow rate: 1000L/HElectrolyte: HCLVoltage: 380V/50HzElectric Current:3500WProduct advantageHigh concentration hypochlorous acid disinfectant can be prepared continuouslyThe electrolytic cell will not be affected by high concentration of hypochlorous acid,electrolysis is sufficient,st
Contact Now
The whole system is equipped with a three-stage hydrogen shooting technology device, the cathode discharged hydrogen during the electrolytic cell electrolysis process, and the hydrogen separator above it can effectively separate the gas and liquid, and timely discharge the hydrogen generated in the electrolytic cell during the electrolytic process. In addition, the storage tank is equipped with a hydrogen fan to dilute the hydrogen concentration to less than 0.5% and discharge it to the outside.
Contact Now
SHC-1000 Hypochlorous acid generator,using no diaphragm electrolytic hydrochloric acid(HCL), can be applied to the preparation of disinfectant,pet disinfection,factory space disinfection etc., directly connected to tap water,no waste water generationProduct parameterProduct model:No diaphragm electrolytic hydrochloric(HCL) hypochlorous acid generator, up to 500PPMWaterflow:1000L/HConcentration:50-500PPMPower:1200WVoltage:220V/50HzNet weight:95kgGross weight:110KGsProduct advantageBuilt-in pure water system,will not produce salt scale,electrolytic cell life is longerSimple operation,high,medium
Contact Now
Hypochlorous Acid Generator-SHC-230 Advantage:* Safe: In completely compliance with the national standards from <Hygienic requirements for disinfectants with chlorine>, <Hygienic requirements for acidic electrolyed water generator>.* Efficient: 1) Sterilization rate 99.9
Contact Now
Super alkaline electrolytic water generator is our independent research and development and production,using the international advanced parts,automatic operation, intelligent connection of varioud cleaning equipment, potassium carbonate as electrolytic raw material,PH value in 10-14 potassium hydroxide solution,with strong oil removal,rust prevention functionProduct parameterPower supply:220V/50HzGenerator power:1.6KwSoftened water or Purified water:Purified water is best, less than 100PPMInlet water pressure:0.1~0.3MpaWater temperature:10~35℃Installation and operating environment temperature:
Contact Now
SHC-1000S Slightly acidic electrolytic water generator equipment, is independently developed by our company, using diaphragm electrolysis,automatic production,stable production,does not change with the adjustment of concentration,source manufacturers,according to customer requirements customized production,concentration,flow,appearance and so on.
Contact Now
SHC-3000S hypochlorous acid generator, using diaphragm electrolytic salt (Nacl) supporting pretreatment +RO system, electrolytic cell life up to 10,000 hours, can be applied to various scenarios of sterilization, disinfection,Product parameterProduct model:Hypochlorous acid generators are used in food processingWaterflow:1000L/HConcentration:50-300PPMPower:1200WVoltage:220V/50HzNet weight:75kgGross weight:95kgProduct advantageBuilt-in pure water system,will not produce salt scale,electrolytic cell life is longerSimple operation,high,medium,low optionalPLC control,boot 1-3 seconds can produce h
Contact Now
Medical hypochlorous acid generator using diaphragm electrolytic salt(Nacl), supporting RO reverse osmosis system.
Contact Now
Hygiene status of livestock farmingWith the continuous improvement of the scale of livestock and poultry breeding, the centralized production and random stacking of livestock and poultry manure and urine have made the environmental pollution problem caused by livestock and poultry breeding more and more serious.
Contact Now
Strong alkaline electrolytic water has no carbon oil,natural rust prevention function,is a good environmental cleaning liquid,not only decontamination,oil removal,fast speed,but also on the surface of metal parts rust prevention effect,clean water after simple oil and water separation,reach the direct discharge standard,but also reduce the production of environmental pressure of pollution.Product parameterPreparation method :acid-base separation electrolysisElectrolytic cell life:10000HWater flow:1000L/HElectroly materal:potassium carbonatePH:12+-0.5Power requirements:AC380VRated pow
Contact Now
Many crops in the case of continuous planting, there will be repeated cropping (also known as continuous cropping) obstacles, mainly because of repeated cropping easy to lead to the accumulation of soil diseases, soil salinization, nutritional imbalance, the lack of some mineral trace elements and other problems, and then cause plant rot, dead, dead seedlings, no roots and low crop yield, research shows that, The use of electrolytic potassium chloride hypochlorite generator to irrigate soil can kill harmful bacteria in soil, crop blight and cataplasis are effectively controlled.
Contact Now
Product DetailsThe sodium hypochlorite generator uses SHINE proprietary technology electrodes to achieve superior salt water electrolysis efficiency and energy-saving effects. The SHINE system has been successfully deployed in small water treatment plants and sewage treatment plants both domestically and internationally for many years, and more and more customers have proven its safety and superiority.
Contact Now
Hygiene status of livestock farmingWith the continuous improvement of the scale of livestock and poultry breeding, the centralized production and random stacking of livestock and poultry manure and urine have made the environmental pollution problem caused by livestock and poultry breeding more and more serious.
Contact Now
2000L/H Electrolytic Hydrochloric Acid (HCL),High-concentration Hypochlorous Acid Generator.Using fully automatic industrial equipment,Siemens high-end PLC control,one-touch,supporting remote control system,float switch automatic start and stop,fault equipment automatic alarm,the disply can display PH,ORP, concentration,flow and other parameters in real timeHigh Concentration Hypochlorous Acid Generator ParameterProduct ModelHigh Concentration Hypochlorous Acid Generator(HCL)Voltage380V/50HzRated Power100-2500W(adjustable)Concentration50-500PPMPH5-6.5ORP800MVFlow2000L/ HElectrolyteHydrochloric
Contact Now
Product DetailsThe electrolysis system adopts the patented technology design of "modular sodium hypochlorite generator", with high integration and simple and convenient installation, operation and maintenance.Product parameterEffective chlorine production: 50-500g/HEffective chlorine concentration: 8-10g/LInstalled power: 0.3-2.4KWHost size: 700 * 450 * 900Delivery cycle: 15 daysWhatsApp:+86 19953182842Email: henry@hoclshine.comProduct advantage1、The core component electrodes of the generator, both positive and negative electrodes, are made of pure titanium as the substrate, and the
Contact Now
Product Details SHINE brand electrolytic salt method 0.4% -0.8% concentration sodium hypochlorite generator is composed of four parts: an automatic salt dissolving box, an ion membrane electrolysis tank, an electrolysis power supply, and a sodium hypochlorite generation and storage system.
Contact Now
Sodium Hypochlorite Generator of ElectrolyticThe advantage of the electrolytic Sodium Hypochlorite Generator is that it can generate sodium hypochlorite as needed without storing or transporting hazardous hypochlorite.
Contact Now
Hypochlorous Acid produced by Hypochlorous Acid Generator has low cost,bactericidal rate as high as 99.99%,and no waste water is produced.Concentration 50-500PPM (adjustable),the flow is stable,not affected by high and low concentrationsHOCL Generator Product ParameterProduct NameCommercial Hypochlorous Acid GeneratorElectrolyteHCL(5%)HOCL Output300L/HConcentration50-500PPMPH5.0~6.5ORP>800MVN.W35KGSG.W45KGSSize390*340*910mmPacking Size485*450*1030mmHypochlorous Acid Generator Product AdvantageIndependent research and development of electrolytic cell,No diaphragm electrolysis,life of 10000HI
Contact Now
Hypochlorous Acid Generator-SHC-230 Advantage:* Safe: In completely compliance with the national standards from <Hygienic requirements for disinfectants with chlorine>, <Hygienic requirements for acidic electrolyed water generator>.* Efficient: 1) Sterilization rate 99.9
Contact Now