SHC-300Y Hypochlorous Acid Generator - Generate Hypochlorous Acid (HOCL) up to 500 ppm
SHC-300 Hypochlorous Acid Generator is using the self-developed non-diaphragm electrochemical technology, the safe, effective, non-toxic, non-irritating and environmentally friendly hypochlorous acid disinfection water in the range of 3-500ppm can be quickly and efficiently prepared in 1-3 seconds after starting the machine.
Model No.: SHC-300Y
Machine Size: 450*350*1300mm
Water Production: 300L/hour
Concentration PPM: 3-500ppm
PH Concentration: 5.0-6.5
ORP: >800mv
Hypochlorous Acid Generator-SHC-300Y
Advantage:
* Safe:
In completely compliance with the national standards from <Hygienic requirements for disinfectants with chlorine>, <Hygienic requirements for acidic electrolyed water generator>.
* Efficient:
1) Sterilization rate 99.99%;
2) Sterilization time: within 1minute.
* Environmently Friendly:
1) The pH value is between 5-6.5, it is slightly acidic, colorless, non-irritating, non-toxic, safe, harmless and no harm to the skin;
2) It ends with water.
*Convenient and Economic:
Open and use, cleaning and disinfection two-in-one
*Multiple Functions:
Sterilization, preservation, deodorization, pesticide residue removal, biofilm removal
Scope of Application:
Product application video
1. Public transportation area: reception desks, hallwalls, grounds, waiting rooms, toll surfaces, canteens and toilets etc.
2. Hospital: outpatient room, infusion room, inpatient ward, office, etc.
3. Office:Telephones, Faxes, Printers, Keyboards, and Mouses etc.
4. Kitchen: Kitchenware, Cookware, Vegetables and Fruits etc.
5. Object surfaces : door handles, window handles, countertops, tables and chairs, handrails, faucets, outer walls of tea buckets,
elevator handrails, elevator buttons, secondary water supply equipment and facilities, etc.
6. Air disinfection: disinfection and deodorization of indoor and outside air.
7. Cleaning tools: towels, rags, mops, buckets, brushes, etc.
8. Personal hygiene: hands, skin and mucous membranes.
Products Parameter:
Concentration PPM | 3-500ppm |
Flow | 300L/hour |
Available chlorine concentration | 3-500mg/L |
Power requirements | AC220V 50Hz |
Power | 455W |
Current setting value | 0.1-2.2A |
Electrolyte | dilute HCL |
Water inlet pressure | 0.15Mpa---0.25Mpa |
Electrolyzer life | 6000 hours |
Size | 450*350*1300mm |
Available chlorine concentration testing video
pH value testing video
Our Factory:
Qualification Patent:
Submitted successfully
We will contact you as soon as possible